Інструкція По Експлуатації Газ 24
EN OWNER S MANUAL Split Air Conditioner Vip Inverter Series MODELS: CH-S09FTXHV-B CH-S12FTXHV-B CH-S18FTXHV-B For proper operation, please. (Smart Phone, Tablet PC).16 Emergency operation.24 Maintenance Clean and maintenance Malfunction Malfunction analysis Installation Notice Installation.
In Yellow Hats, understanding the needs of clients is our professional duty. We individually assess each plan and offer optimal solutions, proceeding from the project’s objectives and specifics. The company’s stable financial standing enables us to set minimal advance payment rates and a comfortable schedule of financing for the client. The perfectly built management system provides for effective communications between all project stakeholders at every stage of their cooperation. Engagement with the client is based on the “one contact” principle the project manager keeping in touch all days long. In Yellow Hats, understanding the needs of clients is our professional duty.
We individually assess each plan and offer optimal solutions, proceeding from the project’s objectives and specifics. The company’s stable financial standing enables us to set minimal advance payment rates and a comfortable schedule of financing for the client. The perfectly built management system provides for effective communications between all project stakeholders at every stage of their cooperation. Engagement with the client is based on the “one contact” principle the project manager keeping in touch all days long.
In Yellow Hats, understanding the needs of clients is our professional duty. We individually assess each plan and offer optimal solutions, proceeding from the project’s objectives and specifics. The company’s stable financial standing enables us to set minimal advance payment rates and a comfortable schedule of financing for the client.
The perfectly built management system provides for effective communications between all project stakeholders at every stage of their cooperation. Engagement with the client is based on the “one contact” principle the project manager keeping in touch all days long.
1 EN OWNER S MANUAL Split Air Conditioner Vip Inverter Series MODELS: CH-S09FTXHV-B CH-S12FTXHV-B CH-S18FTXHV-B For proper operation, please read and keep this manual carefully. Designed by Cooper&Hunter International Corporation, Oregon, USA 2 Specialties note Matching instructions This model adopts RF remote control.
The remote controller shall be matched with the air conditioner before operation, otherwise the remote control will be invalid. Before operation, please read the instructions in this page carefully and then do the corresponding matching operation. Note Please done the following operation within 2m from the unit. Matching is not needed anymore once it is done. During matching, please keep the remote controller and air conditioner under standby status. When the signal of remote controller can t be received, please match the remote controller with the unit again.
Matching of remote controller When the unit is under standby status, please get close to the air conditioner within 2m and then hold on pressing Humidify/Health button for 3s. The remote controller and air conditioner will enter matching automatically. If matching is done, the unit will give out three sounds; if matching is failed, please get closer to the unit and arrange matching again. 3 Content Operation Notices Precautions.1 Parts name. 6 Screen Operation Guide Buttons on remote controller. 7 Introduction for icons on display screen.
7 Introduction for buttons on remote controller. 10 Buttons on remote controller Introduction for icons on display screen Operation mode Auto mode Cool mode Dry mode Fan mode Heat mode Set time Turbo fan speed X-FAN function Auto quiet mode:Set temp. INTELLIGENT HOUR ON OFF Quiet mode Temp. Display type:Outdoor ambient temp. 7 1 ON/OFF button 2 +/- button 3 Cool button 4 Heat button 5 Fan button 6 I FEEL button 7 up down swing button 8 Mode button 9 Left right swing button 10 T-ON/T-OFF button 11 Clock button 12 Humidity button/health button 13 X-fan button 14 Air button 15 Light button 16 Sleep button 17 WIFI button WIFI:Indoor ambient temp. Set fan speed Send signal battery power humidity functions Temp.display type Healthy mode Set temperature Up & down swing Left & right swing 8 heating function child lock I feel function Replacing air Sleep mode 11 Introduction for buttons on remote controller Note: After putting through the power, the air conditioner will give out a sound. Operation indictor ' ' is ON (red indicator).
After that, you can operate the air conditioner by using remote controller. Under on status, pressing the button on the remote controller, the signal icon ' ' on the display of remote controller will blink once and the air conditioner will give out a de sound, which means the signal has been sent to the air conditioner. 1 2 Press '+' or ' - ' button once increase or decrease set temperature 0.5. Holding '+' or ' - ' button, 2s later, set temperature on remote controller will change quickly.on releasing button after setting is finished, temperature indicator on indoor unit will change accordingly. (Temperature can t be adjusted under auto mode) When setting TIMER, press '+' or ' - ' button to adjust time. 5 ON/OFF button Press this button can turn on or turn off the air conditioner. After turning on the air conditioner, operation indicator ' 'on indoor unit s display is ON (green indicator.
The colour is different for different models), and indoor unit will give out a sound. 3 +/- button Cool button Press this button, unit will operate in cool mode. 4 Heat button Press this button, unit will operate in heat mode. FAN button Pressing this button can set fan speed circularly as: low( ), low medium( ), medium ( ),medium high( ),high( ),super( ),auto(auto),quiet( ).
Auto Note: Turbo function is not available under dry and auto mode. Automatically operate slient speed when starting sleep fuction.
The unit operates at low speed under dry and auto dry mode. The speed can't be adjusted. Under AUTO speed, air conditioner will select proper fan speed automatically according to ambient temperature. 8 12 Introduction for buttons on remote controller 6 I FEEL button Press this button to start I FEEL function and ' ' will be displayed on the remote controller. After this function is set, the remote controller will send the detected ambient temperature to the controller and the unit will automatically adjust the indoor temperature according to the detected temperature.
Press this button again to close I FEEL function and ' ' will disappear. Please put the remote controller near user when this function is set. Do not put the remote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature. 7 button Under simple swing mode, press this button can turn on (display ' ' icon ) or turn off ( not display ' ' icon) left&right swing function. Under OFF status, press '+' button and ' ' button simultaneously can switch between simple swing mode and fixed swing mode. During switching time, icon on remote controller will flash twice. Under fixed-angle swing mode, press this button and the left and right swing status will change in the sequence as below: no display (stops at current position) 8 MODE button Press this button to select your required operation mode.
AUTO COOL DRY FAN HEAT 9 13 Introduction for buttons on remote controller When selecting auto mode, air conditioner will operate automatically according to ambient temperature. Set temperature can t be adjusted and will not be displayed as well. Press 'FAN' button can adjust fan speed. Press ' ' / ' ' button can adjust fan blowing angle.
After selecting cool mode, air conditioner will operate under cool mode. Press '+' or '-' button to adjust set temperature. Press 'FAN' button to adjust fan speed.press ' ' / ' ' button to adjust fan blowing angle. When selecting dry mode, the air conditioner operates at low speed under dry mode.
Under dry mode, fan speed can t be adjusted. Press ' ' / ' ' button to adjust fan blowing angle. When selecting fan mode, the air conditioner will only blow fan,press 'FAN' button to adjust fan speed. Press ' ' / ' ' button to adjust fan blowing angle.
When selecting heating mode, the air conditioner operates under heat mode. Press '+' or '- ' button to adjust set temperature. Press 'FAN' button to adjust fan speed.
Press ' ' / ' ' button to adjust fan blowing angle. (Cooling only unit won t receive heating mode signal. If setting heat mode with remote controller, press ON/OFF button can t start up the unit).
Note: For preventing cold air, after starting up heating mode, indoor unit will delay 1~5 minutes to blow air (actual delay time is depend on indoor ambient temperature). Set temperature range from remote controller: 16~30 (61-86 F); 9 button Under simple swing mode, press this button can turn on ( display ' ' icon) or turn off ( not display ' ' icon) up&down swing function. Under OFF status, press '+' button and ' ' button simultaneously can switch between simple swing mode and fixed swing mode. During switching time, icon on remote controller will flash twice. Under fixed swing mode, press this button and up and down swing status will change in the sequence as below: no display (horizontal louvers stops at current position) 10 14 Introduction for buttons on remote controller 10 T-ON/T-OFF button T-ON button T-ON button can set the time for timer on. After pressing this button, ' ' icon disappears and the word ON' on remote controller blinks. Press + or - button to adjust T-ON setting.
After each pressing + or - button, T-ON setting will increase or decrease 1min. Hold + or - button, 2s later, the time will change quickly until reaching your required time. Press T-ON to confirm it. The word ON will stop blinking. ' ' icon resumes displaying.cancel TIMER ON: Under the condition that T-ON is started up, press T-ON button to cancel it.
T-OFF button T-OFF button can set the time for timer off. After pressing this button, ' ' icon disappears and the word 'OFF' on remote controller blinks. Press '+' or '-' button to adjust T-OFF setting. After each pressing '+' or '-' button, T-OFF setting will increase or decrease 1min.
Hold '+' or '-' button, 2s later, the time will change until reaching your required time. Press T-OFF to confirm it. The word ON will 'OFF' will stop blinking. ' ' icon resumes displaying. Cancel T-OFF.Under the condition that T-OFF is started up, press T-OFF button to cancel it. Note: Under on and off status, you can set T-OFF or T-ON simultaneously. Before setting T-ON or T-OFF, please adjust the clock time.
After starting up T-ON or T-OFF, set the constant circulating valid. After that, air conditioner will be turned on or turned off according to setting time. ON/OFF button has no effect on setting. If you don t need this function, please use remote controller to cancel it. 11 CLOCK button Press this button to set clock time. ' ' icon on remote controller will blink.
Press '+' or '-' button within 5s to set clock time. Each pressing of '+' or '-' button, clock time will increase or decrease 1 minute.
Hold '+' or '-' button, 2s later, time will change quickly. Release this button when reaching your required time. Press CLOCK button to confirm the time.
' ' icon stops blinking. Note: Clock time adopts 24-hour mode. The interval between two operations can t exceeds 5s. Otherwise, remote controller will quit setting status. Operation for TIMER ON/TIMER OFF is the same. 11 15 Introduction for buttons on remote controller 12 Humdity/health button Press this button to select your required operation mode.
INTELLIGENT INTELLIGENT cancel Note:there is no this function for this unit. If press this button,the main unit will click, but it also runs under original status. 13 X-FAN button Pressing this button in COOL or DRY mode, the icon ' ' is displayed and the indoor fan will continue operation for 2 minutes in order to dry the indoor unit even though you have turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is not available in AUTO, FAN or HEAT mode. This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould. Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for about 2 min.
At low speed. In this period, press X-FAN button to stop indoor fan directly. Having set X-FAN function off: After turning off the unit by pressing ON/OFF button, the complete unit will be off directly. 14 Air button Press this button to select your required operation mode. Cancel Note:there is no this function for this unit.
If press this button,the main unit will click, but it also runs under original status LIGHT button Pressing this button to turn off display light on indoor unit. Press this button again to turn on display light. SLEEP button Pressing this button can select Sleep 1, Sleep 2,Sleep 3, Sleep 4 or cancel Sleep circularly as below: cancel 12 16 Introduction for buttons on remote controller In Sleep 1 and Sleep 2, the air conditioner will run according to a group of presetting temperature curves. Sleep 3 - the sleep curve setting under DIY Sleep mode: (1) Under Sleep 3 mode, long press 'AIR' button, the remote controller will enter the setting of personalized sleep.
In this case, the timer zone of remote controller will display '1 hr' and the set temperature zone '88' will display the corresponding temperature of the last set sleep curve and blink (The first entering will display according to the initial curve setting value of manufacturer); (2) Press '+' and '-' button to adjust the corresponding temperature. After adjusting, press 'AIR' button to confirm it; (3) At this time, the timer time on the remote controller will increase automatically by 1hr (that is '2 hr' or '3 hr' or '8 hr').
The set temperature zone '88' will display the corresponding temperature of the last set sleep curve and blink; (4)Repeat step(2) and step (3) until 8-hour temperature setting is finished, then the sleep curve is set successfully. After that, remote controller will resume displaying the original timer time and temperature zone will resume displaying the original set temperature. Sleep 3 - the sleep curve inquiry under DIY Sleep mode: User can inquire the set sleep curve according to the setting method of sleep curve. Enter the setting of personalized sleep but do not change the temperature. Then press 'AIR' button to confirm the setting.
Note: In the above setting or inquiry procedure, if there is no button pressing within 10s, remote controller will automatically exit the sleep curve setting and resume the HEATING button is pressed during the setting or inquiry procedure, remote controller original display. If ON/OFF, MODE, TIMER, HUMIDIFY, SLEEP, COOLING or will also exit the sleep curve setting. Sleep 4 is Siesta mode. The set temperature will change automatically according to the features of siesta.
Sleep function will be disabled if the air condition is restarted after power failure; when sleep function is turned on, quite fan speed will be also turned on. Sleep function can not be set in AUTO mode. 17 Wifi button Press this button 3s can set wifi function on or OFF. At OFF status,press mode button and wifi button,can reset wifi mode parameter.
And open wifi function. 13 17 Function introduction for combination buttons About X-FAN function This function indicates that moisture on evaporator of indoor unit will be blowed after the unit is stopped to avoid mould.
Having set X-FAN function on: After turning off the unit by pressing ON/OFF button indoor fan will continue running for about 2 min. At low speed.
In this period, press X-FAN button to stop indoor fan directly. Having set X-FAN function off: After turning off the unit by pressing ON/OFF button, the complete unit will be off directly. About AUTO RUN When AUTO RUN mode is selected, the setting temperature will not be displayed on the LCD, the unit will be in accordance with the room temp. Automatically to select the suitable running method and to make ambient comfortable. About lock Press + and - buttons simultaneously to lock or unlock the keyboard.
If the remote controller is locked, the icon will be displayed on it, in which case, press any button, the mark will flicker for three times. If the keyboard is unlocked, the mark will disappear. About switch between Fahrenheit and Centigrade Under status of unit off, press MODE and - buttons simultaneously to switch and. 14 18 Operation guide 1. After putting through the power, press 'ON/OFF' button on remote controller to turn on the air conditioner.
Press 'MODE' button to select your required mode: AUTO, COOL, DRY, FAN, HEAT. Press '+' or ' - ' button to set your required temperature.
(Temperature can t be adjusted under auto mode). Press 'FAN' button to set your required fan speed: auto, low, medium and high speed. Press 'SWING' button to select fan blowing angle. Replacement of batteries in remote controller 1. Press the back side of remote controller marked signal sender battery the cover of battery box along the arrow direction. Replace two 7# (AAA 1.5V) dry batteries, and make sure the position of '+' polar and '-' polar are correct. Reinstall the cover of battery box.
Reinstall remove Cover of battery box Battery level will be displayed on the remote controller.when ' ' is flickering, please replace the batteries, otherwise, remote controller can t operate normally. Battery level NOTICE During operation, point the remote control signal sender at the receiving window on indoor unit. The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles between them.
Signal may be interfered easily in the room where there is fluorescent lamp or wireless telephone; remote controller should be close to indoor unit during operation. Replace new batteries of the same model when replacement is required. When you don t use remote controller for a long time, please take out the batteries. If the display on remote controller is fuzzy or there s no display, please replace batteries. 15 19 Operation of Smart Control (Smart Phone, Tablet PC) Special Function How to operate AC or auxiliary device with smart phone or tablet PC after matching: First of all: before using smart connection function, please make sure your smart phone or tablet computer uses the standard Android or ios operating system.
Please refer to the application program for the specific version. This air conditioner can connect 4 smart phones or tablet computers in maximum. Install G-Life on your smart phone/ tablet PC Method 1: Link for Android: Method 2: Scan the QR code and download the application directly (If your device is not compatible, please download the application in other ways.) Android (.apk): Apple s App Store: Method 3: Users of ios system can search the application G-Life through Apple s App Store. After it is successfully installed, you will see the picture below. Following is the example using iphone 6. (The interface of the application may vary as it is upgraded or used in different operating systems.
Please refer to actual application.) 16 20 Operation of Smart Control (Smart Phone, Tablet PC) 2. Turn on the AC WiFi: Turn the AC on. First, make sure the remote controller is matched. Then, long-press WiFi button on the remote controller for at least 3 seconds.
If WiFi icon is shown, it means the WiFi function is turned on. Enter the WiFi setting of your phone and search for the wireless network named G-xxxxxxxx. Take G-A0B40030 as an example. Connect the network. Input the original password or to connect the network. Open the application software and click Refresh, and then system will link with the air conditioner automatically.
Click to turn on the control function, and then clock any position on the interface and then software will switch to the remote control interface. 17 21 Operation of Smart Control (Smart Phone, Tablet PC) Attention: please change the name and key of the network during the first setting! Left-slide the bottom function bar to Settings and click it to enter into internet setting interface. Click Network Setting, and input user name and password (the defaulted user name and password is admin) in the Login dialog box to enter into Network Setting to modify network name (e.g. G-myhome) and password (refer to the attachment: safe mode and password instruction). After modifying name and password, click it to return and there will be a prompt box, and then clock OK to finish the modification.
Meanwhile, the software will turn back to interface of Air-Conditioner and the AC list will be gone. Exit the application and enter your phone s WiFi Setting. Then you will see the network you just named G-myhome'.
Click it and input the password set in step 6 to join the network. 18 22 Operation of Smart Control (Smart Phone, Tablet PC) 9. Enter into the software interface again. Meanwhile, the short-distance remote control setting for your air conditioner is finished. How to reset the AC WiFi module: Turn unit off with the remote controller and disconnect the power of AC. Then re-connect the power.
1 minute later, press WiFi and Mode buttons simultaneously. If the AC gives out a beep sound, it means the WiFi module is successfully reset. Attention: Operation of the buttons is only effective in 2 minutes. Analysis on Common Network Setting Failure: 1.
If short-distance control fails, please check the following items one by one! Make sure AC is power connected; Make sure AC s WiFi function is turned on as normal; Make sure your phone s WiFi selects the corresponding AC; Reset with the remote controller and then start setting again from step 3. Kindly remind: 1. The air conditioner WiFi function needs about 1 minute to start up. The air conditioner has memory function. Those models have no long-distance control.
19 23 Operation of Smart Control (Smart Phone, Tablet PC) Function Introduction on Main Interface 1. Mode: It used for setting operation mode for air conditioner. You can select Auto, Cooling, Drying, Fan or Heating according to your requirement.
Please refer to the part of remote controller for the detailed operation. Temperature: It used for setting temperature. Set the indoor temperature according to your requirement.
Fan Speed: It used for setting fan speed. Under cooling or heating mode, if the noise-customized function is turned on, adjust the fan speed and then the noise- -customized function will be turned off automatically.
Please refer to the part of remote controller for detailed operation. 20 24 Operation of Smart Control (Smart Phone, Tablet PC) Key Functions Instruction of Application Software 1.
Preset: It s with Timer On and Timer Off function. User can set Timer On and Timer Off according to actual individual requirement. 2.Functions: After entering setting interface, you can turn on or turn off Light, Purify, X-fan and Turbo functions and set Silent, Humidify, Air exchange and other modes. Please refer to the part of remote controller for the function instruction. Among that, Purify, Humidify, Air exchange functions can be set through equipping with special air purifier, humidifier. E-heater is not available for this unit.
Swing: During up&down swing and left&right swing, it s the fixed angle swing when those two sliding blocks are combined together and full swing when they are separated. When setting up&down swing, the program will turn off regional swing function. However, no influence for regional swing when setting left&right swing. 21 25 Operation of Smart Control (Smart Phone, Tablet PC) 4. Advanced: After entering advanced interface, you can set Sleep curve, Regional Swing, Noise and Power saving. Sleep curve: Sleep curve includes DIY mode, Traditional mode, Expert mode and Siesta mode. Under DIY mode, you can set temperature and time.
Under auto mode and fan mode, sleep curve function can t be turned on. Only Traditional mode can be selected under dry mode. Regional Swing: After entering Regional Swing, user can set it according to the room size. Press Air flow position button and the user can adjust the fan-blowing area through moving the icon of air conditioner left and right according to the actual installation position of the unit. User can move the person icon among nine pane areas according to requirement to adjust the fan-blow area. The Regional Swing function can be turned off through up&down swing.
The up&down swing in the Regional Swing is only valid under cooling and heating modes. The left&right swing area has relationship with the position of air conditioner set by mobile phone. The left&right swing position may be asymmetry, which is the normal phenomenon. Avoid people function can be turned on or turned off according to user s personal experience. There may be deviation because of the installation position of air conditioner and the setting of parameters, which is the normal phenomenon. 22 26 Operation of Smart Control (Smart Phone, Tablet PC) Noise: The noise-customized function for indoor unit can be adjusted according to the actual individual requirement. The detailed adjustment range is different for different models, which is decided by indoor unit.
Power saving: After energy saving navigation mode is turned on, the air conditioner will detect indoor temperature and outdoor temperature automatically. Meanwhile, the air conditioner will adjust frequency, fan speed and set temperature automatically according to the load status for saving energy. 23 27 Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode. Panel Display panel aux. Button WARNING: Use insulated object to press the auto button Clean and maintenance WARNING Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock.
Do not wash the air conditioner with water to avoid electric shock. Do not use volatile liquid to clean the air conditioner. Clean surface of indoor unit When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth or wet cloth to wipe it. NOTICE: Do not remove the panel when cleaning it.
24 28 Clean and maintenance 1 Open panel Open the panel into a certain angle(less than 60, do not open the panel too forcibly) along the arrow direction from the two sides of panel. 3 Use dust catcher or water to the water (below 45 ) to clean it, and then put it in a shady and cool place to dry. 2 4 Install the filter and then close the panel cover tightly.(press the arrow (1) position to check whether it buckled tightly. ) (1) (1) (1) WARNING operation environment, clean frequency can be increased. 25 29 Clean and maintenance NOTICE: Checking before use-season 1. Check whether air inlets and air outlets are blocked. Check whether air switch, plug and socket are in good condition.
Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer. Check whether drainage pipe is damaged. NOTICE: Checking after use-season 1. Disconnect power supply.
Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer. Notice for recovery 1. Many packing materials are recyclable materials. Please dispose them in appropriate recycling unit. If you want to dispose the air conditioner, please contact local dealer or consultant service center for the correct disposal method. 26 30 Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance.
If the malfunction still can t be eliminated, please contact local dealer or qualified professionals. Phenomenon Check items Solution Whether it's interfered severely (such as static electricity,stable voltage)? Whether remote controller is within the signal receiving range? Pull out the plug. Reinsert the plug after about 3min, and then turn on the unit again. Signal receiving range is 8m. Indoor unit can t receive remote controller s signal or remote controller has no action.
Whether there are obstacles? Whether remote controller is pointing at the receiving window? Is sensitivity of remote controller low; fuzzy display and no display? No display when operating remote controller?
Fluorescent lamp in room? Remove obstacles. Select proper angle and point the remote controller at the receiving window on indoor unit. Check the batteries. If the power of batteries is too low, please replace them. Check whether remote controller appears to be damaged. If yes, replace it.
Take the remote controller close to indoor unit. Turn off the fluoresent lamp and then try it again.
No air emitted from indoor unit Air inlet or air outlet of indoor unit is blocked? Under heating mode, indoor temperature is reached to set temperature?
Heating mode is turned on just now? Eliminate obstacles. After reaching to set temperature, indoor unit will stop blowing out air. In order to prevent blowing out cold air, indoor unit will be started after delaying for several minutes, which is a normal phenomenon.
27 31 Malfunction analysis Phenomenon Check items Solution Air conditioner can t operate Mist is emitted from indoor unit s air outlet Set temperature can t be adjusted Cooling (heating) effect is not good. Power failure?
Is plug loose? Air switch trips off or fuse is burnt out? Wiring has malfunction? Unit has restarted immediately after stopping operation?
Whether the function setting for remote controller is correct? Indoor temperature and humidity is high? Unit is operating under auto mode? Your required temperature exceeds the set temperature range?
Voltage is too low? Filter is dirty? Set temperature is in proper range? Door and window are open? Wait until power recovery.
Reinsert the plug. Ask professional to replace air switch or fuse. Ask professional to replace it. Wait for 3min, and then turn on the unit again. Reset the function.
Because indoor air is cooled rapidly. After a while, indoor temperature and humidity will be decrease and mist will disappear. Temperature can t be adjusted under auto mode. Please switch the operation mode if you need to adjust temperature. Set temperature range: 16 ~30. Wait until the voltage resumes normal.
Clean the filter. Adjust temperature to proper range. Close door and window. 28 32 Malfunction analysis Phenomenon Check items Solution Odours are emitted Whether there s odour source, such as furniture and cigarette, etc. Eliminate the odour source. Clean the filter.
Ethno World 3 Complete Keygen there. Air conditioner operates normally suddenly Whether there s interference, such as thunder, wireless devices, etc. Disconnect power, put back power, and then turn on the unit again.
Outdoor unit has vapor Heating mode is turned on? During defrosting under heating mode, it may generate vapor, which is a normal phenomenon. Water flowing noise Air conditioner is turned on or turned off just now?
The noise is the sound of refrigerant flowing inside the unit, which is a normal phenomenon. Cracking noise Air conditioner is turned on or turned off just now? This is the sound of friction caused by expansion and/or contraction of panel or other parts due to the change of temperature. 29 33 Malfunction analysis Error Code When air conditioner status is abnormal, temperature indictor on indoor unit will ation of error code. Error code E5 E6 Troubleshooting It can be eliminated after restarting the unit. If not, please It can be eliminated after restarting the unit. If not, please E8 U8 H6 It can be eliminated after restarting the unit.
If not,please It can be eliminated after restarting the unit. If not,please It can be eliminated after restarting the unit. If not,please C5 F1 F2 Note: If there're other error codes, please contact qualified professionals for service. WARNING When below phenomenon occurs, please turn off air conditioner and disconfor service. Power cord is overheating or damaged. There s abnormal sound during operation.
Air switch trips off frequently. Air conditioner gives off burning smell. Indoor unit is leaking. If the air conditioner operates under abnormal conditions, it may cause 30 34 Installation dimension diagram At least 250cm Space to the ceiling At least 15cm Space to the wall At least 15cm Space to the wall At least 15cm At least 300cm Space to the obstruction 31 35 Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note: Please contact the local agent for installation.
Arcadia So Red The Rose Remastered here. Selection of installation location Basic requirement Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local dealer: 1.The place with strong heat sources,, or volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine, medical equipment). 3.The place near coast area. 4.The place with oil or fumes in the air. 5.The place with sulfureted gas. 6.Other places with special circumstances. 7.The appliance shall not be installed in the laundry.
Indoor unit 1. There should be no obstruction near air inlet and air outlet. Select a location where the condensation water can be dispersed easily and won't affect other people. Select a location which is convenient to connect the outdoor unit and near the power socket. Select a location which is out of reach for children. The location should be able to withstand the weight of indoor unit and won't increase noise and vibration. The appliance must be installed 2.5m 7.
Don't install the indoor unit right above the electric appliance. Please try your best to keep way from 32 36 Requirements for electric connection Safety precaution 1.
Must follow the electric safety regulations when installing the unit. Make sure the power supply matches with the requirement of air conditioner. Unstable power supply or incorrect wiring or malfunction.
Please install proper power supply cables before using the air conditioner. Properly connect the live wire, neutral wire and grounding wire of power socket. Be sure to cut off the power supply before proceeding any work related to electricity and safety.
If the supply cord is damaged, it must be replaced by the manufacturer, its 8. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
The appliance shall be installed in accordance with national wiring regulations. Grounding requirement grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. The yellow-green wire in air conditioner is grounding wire, which can't be used for other purposes.
The grounding resistance should comply with national electric safety regulations. The appliance must be positioned so that the plug is accessible. An all-pole disconnection switch having a contact separation of at least 3mm in For models with a power plug, make sure the plug is within reach after installation 33 37 Installation of indoor unit Step one: choosing installation location rm it with the client. Step two: install wall-mounting frame 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the plastic expansion particles in the holes. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and. Step three: open piping hole 1.
Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame, shown as below. 09 K 12K: 18K: Wall Mark in the middle of it Space to the wall above 150mm Level meter Space to the wall above 150mm Wall Wall Mark in the middle of it Space to the wall above 150mm Level meter Space to the wall above 150mm Wall Left Φ55mm Rear piping hole Right Φ55mm Rear piping hole Left Φ55mm Rear piping hole Right Φ55mm Rear piping hole 2.
Open a piping hole with the diameter of Φ55 on the selected outlet pipe position.in order to drain smoothly, slant the piping hole on the wall slightly downward to the outdoor side with the gradient of 38 Installation of indoor unit Note: Pay attention to dust prevention and take relevant safety measures when opening the hole. The plastic expansion particles are not provided and should be bought locally Indoor outdoor Φ55 Step four: outlet pipe 1. The pipe can be led out in the direction of right, rear right, left or rear left. When select leading out the pipe from left or right, please cut off the corresponding hole on the bottom case. Left right rear left right rear right left cut off the hole 1. Aim the pipe joint at the corresponding bellmouth.
Pretightening the union nut with hand. Pipe joint union nut pipe 3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tighten the union nut with torque wrench. 35 39 Installation of indoor unit torque wrench indoor pipe open-end wrench union nut pipe 4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and then wrap it with tape.
Hex nut diameter Φ 6 Φ 9.52 Φ 12 Φ 16 Φ 19 Tightening torque (N.m) 15~20 30~40 45~55 60~65 70~75 insulating pipe Step six: install drain hose 1. Connect the drain hose to the outlet pipe of indoor unit. Drain hose outlet pipe 2.
Bind the joint with tape. Tape Note: Add insulating pipe in the indoor drain hose in order to prevent condensation.
The plastic expansion particles are not provided. Outlet pipe drain hose drain hose insulating pipe Step seven: connect wire of indoor unit pane screw 1. Open the panel, remove the screw on the wiring cover and then take down the cover. 36 wiring cover.